Al Monatg | Bay 3 | 01/10/2018 | 7 | Housekeeping | Very messy in bay 3 | Completed | 02/16/2018 | View / Edit Details | |||
Mike Frieler | Production | 01/10/2018 | 6 | Other | EE unintentionally stepped out in front of the forklift driver. | Completed | 01/10/2018 | View / Edit Details | |||
timothy buchite | farmstead | 01/10/2018 | 5 | Housekeeping | board with nails sticking through | Completed | 01/10/2018 | View / Edit Details | |||
Doug Schleicher | Production Bay 3/Leveler Bay | 01/10/2018 | 10 | Housekeeping | No one is cleaning up the area after using it. Boards with screws and nails on floor and just basic junk laying everywhere. | Completed | 01/10/2018 | View / Edit Details | |||
Andrew Scholten | West Plant | 01/10/2018 | 4 | PPE | Rob Caudill forgot safety glasses when entering the west plant. | Completed | 01/10/2018 | View / Edit Details | |||
Kevin lesto | Fda | 01/09/2018 | 12 | Other | Concrete bridge had no rebar or cable in it. It broke in half and fell into the manlift cutting Phil for head and bruising Jason's shoulder.very lucky that was all | Completed | 01/10/2018 | View / Edit Details | |||
Adam Pogatschnik | Production Floor | 01/09/2018 | 4 | Safe Equipment Operations | Witnessed an employee operating the forklift without wearing their seatbelt. | Completed | 01/10/2018 | View / Edit Details | |||
timothy buchite | Farmstead | 01/09/2018 | 5 | PPE | Hard hat not being worn by carpenters. | Completed | 01/09/2018 | View / Edit Details | |||
Patrick McCarthy | East and West Ends of TT | 01/09/2018 | 6 | Housekeeping | Cable that is waiting to be cut is piled on floor in numerous places creating trip hazards. One pile near East end of TT blocks an exit door. | Completed | 02/23/2018 | View / Edit Details | |||
Tom Lyle | Hollow Core | 01/09/2018 | 9 | Fall Hazard | Guarding chain was not being used for fall protection because chain installed was too short. | Completed | 01/09/2018 | View / Edit Details | |||
Mike Frieler | Production | 01/09/2018 | 3 | PPE | EE was going to go to the floor without a safety vest on. | Completed | 01/09/2018 | View / Edit Details | |||
Jordan Johnson | Building 3 | 01/08/2018 | 5 | Other | Truck drivers parked there trucked in the building over the long weekend. started them all up and left them running in the morning without opening the overhead door. | Completed | 01/10/2018 | View / Edit Details | |||
Chuck Knowles | Yard | 01/08/2018 | 7 | Safe Equipment Operations | C-CAPP panel in Rosemount has a number of pins, that hold the concrete to the steel frame, sheered off from the steel frame. This has created a saftey issue as the item sits on a trailer in the yard. | Completed | 01/12/2018 | View / Edit Details | |||
Mike Frieler | FS-13 | 01/08/2018 | 8 | Safe Equipment Operations | Readi mix driver hit the stressing rack on the end of the bed and bent it. | Completed | 01/09/2018 | View / Edit Details | |||
timothy buchite | farmstead | 01/08/2018 | 5 | Housekeeping | nails sticking up out of 2x4 bracing | Completed | 01/08/2018 | View / Edit Details | |||
Jeff Kemper | West end of metal shop outside of service door | 01/08/2018 | 7 | Safe Equipment Operations | Bundles of rebar are stacked up outside of the west service door. The dunnage between the layers is leaning and it looks like the rebar could possibly fall off. | Completed | 01/10/2018 | View / Edit Details | |||
Tyler Antil | Riser form | 01/08/2018 | 9 | Other | Saw employee get his shirt wrapped in a grinder with a wire wheel on it. | Completed | 01/08/2018 | View / Edit Details | |||
Dave Kelley | Yard | 01/08/2018 | 9 | Safe Equipment Operations | Noticed safety latch missing on the ring spreaders on the 140. | Completed | 01/08/2018 | View / Edit Details | |||
Al Frederikson | Building B, West bay, south east wall. | 01/08/2018 | 4 | Housekeeping | Boxes stacked in front of fire extinguisher, marked yellow zone. | Completed | 01/08/2018 | View / Edit Details | |||
Nick Nelson | Any Walk Way | 01/08/2018 | 9 | Fall Hazard | when ever it snows, it gets icy on the walk ways (ALL OF THEM). | Completed | 01/10/2018 | View / Edit Details | |||
jacob wood | Building A DT1 | 01/08/2018 | 6 | Safe Equipment Operations | Strand ends on DT1 form are not capped. | Completed | 01/08/2018 | View / Edit Details | |||
John Farren | Building B Sout End | 01/08/2018 | 3 | Housekeeping | Retarder mixing area has old cardboard with retarder on it. | Completed | 01/08/2018 | View / Edit Details | |||
Jack Johnston | fs5 | 01/08/2018 | 6 | Housekeeping | west side was cluttered due to stripping | Completed | 01/08/2018 | View / Edit Details | |||
Tyler Antil | Riser form | 01/05/2018 | 10 | Fall Hazard | people crossing form using the strand as a ladder, someone could fall easily. | Completed | 01/05/2018 | View / Edit Details | |||
Roy Hervey | finish building | 01/05/2018 | 7 | Housekeeping | Windsheilds on patching vans very dirty. | Completed | 01/08/2018 | View / Edit Details | |||