SEE Tracker Entries
Name | kristian zapata |
---|---|
Date | 01/26/2022 |
Time | 01:30 PM |
Area | yarding |
Safety Topic | Other |
Severity | 3 |
Exposure | 1 |
Priority | 3 |
TTL Summary | 3 - 5 = Low Risk | 6 - 9 = Moderate Risk | 10 - 12 = High Risk |
Ttl | 7 |
Root Cause(s) | one of the travel lift crews found a rib slab that was cracked down the middle from improper dunnage placement. |
Status | Completed |
Completion Date | 01/26/2022 |
Corrective Action | I called QC to write up an NCR since the piece was already green tagged, he is reaching out to the engineer to see if it needs to be re poured. |
Entry Comments |