SEE Tracker Entries

NameDOUG E GALLEGOS
Date02/18/2022
Time07:00 AM
AreaThe Link At Fitzsimons
Safety TopicUnsafe Operation
Severity4
Exposure3
Priority4
TTL Summary3 - 5 = Low Risk | 6 - 9 = Moderate Risk | 10 - 12 = High Risk
Ttl11
Root Cause(s)

Erected a 36'-8" tall load bearing column missing the (2) v-pocket when it was produced in the plant.
Had to re-shore in the morning with a B-5 from the column horizontal to the shear before we removed the shore on the 2nd to erect the 3rd floor DDT"s.
Once we loaded the 3 DDT's on to the beam supported by the column it twisted the column and pulled the column out of plum by 1 1/2" Bending the B-4 shore that was supporting it East and West
The fix we had to replace the (2) missing V-pockets did not hold the tall column in place

StatusCompleted
Completion Date02/19/2022
Corrective Action

We stopped erection on that bay and pulled it back to plum with cables and coma longs.
Grouted the column that afternoon and poured the NMB bars on Saturday morning.
Proceeded with erection that morning

Entry Comments
Notes for this entry
There are no notes.
West - Field: Alert Level = High Risk (ID: 5f2d669fcc663)
added on February 21, 2022 at 3:15 am

WordPress successfully passed the notification email to the sending server.