Observer NameTom Peterson
Date of Inspection10/03/2019
SiteField (Wells)
Area / JobJob #7063 Litchfield FDA
House Keeping4
Rigging4
Machines and tools4
Falls Hazards3
Comments (Fall Hazards)

Unprotected poured footing created a 7 foot fall hazard. I talked to Mike with Strack and our solution was to cordon off the area to keep everyone out. He told me the pits were scheduled to be filled in on Friday.

PPE & Signage3
Comments (PPE & Signage)

Contract driver was told to put safety glasses on.

Electrical4
Hot Work3
Comments (Hot Work)

Need new bracket on truck mounted fire extinguisher. Dan took the extinguisher off and will mount a new bracket.

Heavy Equipment Operation4
Ergonomics/ Lifting/ Carrying/ Repetitive4
Photos of Issue
Inspection Total33