C.J. MeyerMidwest Wells In the plant by the breakroom door04/14/20227Unsafe Operation

There is a portable table saw and some vacuums in front of the fire extinguisher and eye wash station.

Needs AttentionView / Edit Details
Joseph MooreMountain States West Division Plant Outside production04/14/20229Housekeeping

Mesh used for beds that was taken off the kart and was never cleaned up after cutting. Also left in front of a walkway.

Needs AttentionView / Edit Details
Ron BarnickMidwest Wells Yard04/18/20220Safe Operation

Observed a yard truck driver driving around talking on his cell phone..

Needs AttentionView / Edit Details
Danny SheetzMountain States West Division Plant FB104/21/202212Housekeeping

Flammable aerosal cans were left out on the ground to be run over and left in plate baskets.

Needs AttentionView / Edit Details
Rob weissMidwest Field Green bay wi04/30/20220Safe Operation

Trucker took belts off of load before being in place to pick with crane

Needs AttentionView / Edit Details
Rob weissMidwest Field Green bay wi04/30/20220Safe Operation

Load not tied down before getting in place to pick with crane

Needs AttentionView / Edit Details
Rob weissMidwest Field Green bay wi04/30/20220Safe Operation

Load not tied down

Needs AttentionView / Edit Details
Geoff NorrenaMountain States West Division Plant Outside, Near FB205/10/20226Unsafe Act

Loading scrapped concrete into the truck to haul it away. the truck is parked next to the port-a-potty.
a 500pg piece of concrete being loaded into the truck fell out of the front loader scoop and landed 5 feet away from the toilet.
if it hit the toilet and someone was in there, a serious injury would occur.

Needs AttentionView / Edit Details
Kevin LestoMidwest Field 734605/11/20229Unsafe Act

Is there any reason why these connections weren't on the top of the flat.. Luckily ew were able to find a lift.. 30' in the air off a ladder isn't only not any fun "it's not very safe". Being in a Creamery you have the problem 9f welding around Stainless Stell Equipment which adds a least twice the welding time because we normally have to take the time to cover the Stainless, and normally take 2 worker instead of 1. When the plate connection is on top its much more convenient for everyone involved and much safer

Needs AttentionView / Edit Details
gerald asmusMidwest Wells west plant05/17/20226Housekeeping

employees are leaving scrap steel on the floor around chop saw. slip-trip hazard

Needs AttentionView / Edit Details
Samuel herreraMountain States West Division Field Inside production08/16/20219Unsafe Operation

Juachin Rangel from the stripping crew was removing burke caps on bed 96 and noticed one of the burkes on piece WAS-6032 was not under the cap.

Needs AttentionView / Edit Details
Samuel HerreraMountain States West Division Field QC Lab08/19/20219Other

Big green cylinder brake machine has been leaking hydrolic oil. It was said it was going to be checked and leak has gotten worse.

Needs AttentionView / Edit Details
James HammerlingGreat Lakes Valders - Production Plant 108/18/20213Fall Hazard

Center electrical box in plant 1 north runway is loose and needs to be re-anchored to the concrete. As it is used for a step this creates a fall hazard.

Needs AttentionView / Edit Details
Pete NealMountain States West Division Plant RS108/18/20218Housekeeping

Concrete Spilled on ground next to bed on south side.

Needs AttentionView / Edit Details
Michelle WatrobaMidwest Rosemount Yard08/19/20214Other

planks on north side of building in yard, do not have load capacity listed on them. Pete and I measured and provided the info to Mark to get the load capacity.

Needs AttentionView / Edit Details
Marc StaynerChoose your Division Yard08/19/20215Unsafe Operation

Employees were using grade 70 chain to lift bundles of mesh. They also bent the mesh as they set it on the ground.

Needs AttentionView / Edit Details
Samuel herreraMountain States West Division Field Production area08/20/20219Fall Hazard

Big storm flooded the east side in production area

Needs AttentionView / Edit Details
Mario IbarraMountain States West Division Plant Outside production08/20/202111Unsafe Operation

Flooded due to drains not been cleared.
The fabric was plugged up with mud

Needs AttentionView / Edit Details
Michael ClayMountain States West Division Field Parking lots at office08/19/20215Other

Flooding in the haul rood at the plant. Is an overall hazard to get from the paved lot to the overflow lot.

Needs AttentionView / Edit Details
Thomas LarsonMountain States West Division Plant RACK 2208/20/20217Housekeeping

EXPOSED NAILS ON SPACER UNDER TRAILER NEAR RACK 22

Needs AttentionView / Edit Details
Tim CateMountain States West Division Plant Color room08/19/20215General Communication

The roof is falling

Needs AttentionView / Edit Details
Joseph LinskensMountain States West Division Plant Outside Maintenance08/16/20218Unsafe Act

No safety cap on compressed gas bottles

Needs AttentionView / Edit Details
Jason StanleyGreat Lakes Valders - Production Yard08/18/20210Safe Operation

While driving through yard i witnessed an employee standing on new double bar lift by cab while operator was handling product. I stopped and informed said emplyee that it is a distraction for operator and unsafe for them to be up there to begin with

Needs AttentionView / Edit Details
Joshua AjawailaMountain States West Division Field Daily stripped DT inventory area by East side of DT308/20/20219Housekeeping

Crane can’t drive and put the DTs that just got stripped today due to uneven spots and holes on the road.

Needs AttentionView / Edit Details
Daisy MedranoMountain States West Division Field QC Lab08/21/20210Safe Operation

In QC Lab Cylinder Breaker Just has a red tag saying do not use.

Needs AttentionView / Edit Details
 Name LocationSite Area Date Ttl Safety Topic Root Causes Status Respirator User Name Completion DateEntry