Name | Location | Site | Area | Date | Ttl | Safety Topic | Root Causes | Status | Respirator User Name | Completion Date | Entry |
---|---|---|---|---|---|---|---|---|---|---|---|
Miguel caballero | Mountain States | West Division Field | 2 | 01/19/2022 | 7 | General Communication | Pieces were coming in out of sequence | Completed | 01/21/2022 | View / Edit Details | |
Miguel caballero | Choose your Division | 2 | 01/25/2022 | 3 | General Communication | Heavy Snow and ice | Completed | 01/26/2022 | View / Edit Details | ||
Miguel caballero | Mountain States | West Division Field | 2 | 01/27/2022 | 3 | General Communication | Weather conditions It's killing us | Completed | 01/27/2022 | View / Edit Details | |
Al Montag | 2 | 02/14/2018 | 4 | Fall Hazard | extra strand on floor | Completed | 02/19/2018 | View / Edit Details | |||
Miguel caballero | Mountain States | West Division Field | 210520 | 08/06/2021 | 0 | Safe Operation | Everything went great and safe | Completed | 08/06/2021 | View / Edit Details | |
LISA JAEGER | Great Lakes | Waukesha - Field | 220320 HUB 13 jobsite | 10/26/2021 | 8 | Unsafe Operation | Jobsite access for trucks extremely poor, potential for a lot of jobsite damage and trucks getting stuck. The access route is difficult for trucks(sharp turns and too close together) with too many obstacles. Rain day prior left site in extremely poor condition. Note: photos will not attach, will forward to Mark Stayner | Needs Attention | View / Edit Details | ||
Tom Peterson | 2nd floor | 11/21/2017 | 5 | Housekeeping | Fireproofer wasn’t practicing good housekeeping. | Completed | View / Edit Details | ||||
Chris Jones | Mountain States | West Division Field | 2nd Floor Office | 08/16/2021 | 3 | General Communication | Well.... I found Waldo. Colin is wearing a Waldo shirt today. | Needs Attention | View / Edit Details | ||
Jeff Kemper | 2nd Production Bay | 07/23/2019 | 3 | Housekeeping | Paper cups and garbage laying on the floor on east end of the 2nd production bay by the drinking fountain. | Completed | 07/23/2019 | View / Edit Details | |||
Brent winter | 2nd production bay | 10/09/2019 | 9 | Fall Hazard | safety chain on top of A18 A-Frame was broke in the middle. | Completed | 10/09/2019 | View / Edit Details | |||
Brent winter | 2nd production bay | 08/07/2019 | 3 | Fall Hazard | Seen an employee with his boot laces untied. | Completed | 08/07/2019 | View / Edit Details | |||
Ben Dalsing | 2nd production bay east end | 04/26/2019 | 4 | Safe Equipment Operations | When the sweeping machine is dumped a dust cloud is created in the that area. One option is to dump direct into the compactor. Another option is to put a vacuum on the dumpster and capture the dust during dumping. | Completed | 04/30/2019 | View / Edit Details | |||
Gregg Jacobson | 32" DT form from GF | 05/10/2018 | 9 | Safe Equipment Operations | We relocated the 32" form from GF to Rosemount. The first project called for depressed strand and the MG folks never depressed at Hanson. We had Tom Holmes go to Rosemount to demonstrate our process. The depression frame and Jack was shipped to the Rosemount plant along with the from. The depression shoes where ordered for the Wells 32" form and jack system. The shoes did not fit properly on the jack. They depressed the strand and it was noted that the strand did not stack properly in the shoe. Tom contacted me and we immediately shut it down and had the proper shoes made up... They are presently pouring with the new depression shoes that fit the ram from GF. | Completed | 05/11/2018 | View / Edit Details | |||
Scott Zachman | 3m | 03/30/2018 | 6 | Safe Equipment Operations | no safety line around generals crane | Completed | 03/30/2018 | View / Edit Details | |||
Scott Zachman | 3m | 03/28/2018 | 8 | Fall Hazard | safety cable down | Completed | 03/30/2018 | View / Edit Details | |||
Welding flash | 3m | 01/29/2018 | 3 | Other | Ironworkers Welding by doorway | Completed | 01/29/2018 | View / Edit Details | |||
Scott Zachman | 3m | 01/31/2018 | 6 | Other | Nobody directing traffic | Completed | 01/31/2018 | View / Edit Details | |||
Scottzachman | 3m | 01/30/2018 | 6 | Housekeeping | General not cleaning up | Completed | 01/30/2018 | View / Edit Details | |||
Dan Jensen | 3M | 06/12/2020 | 9 | Unsafe Operation | The use of Tapcon fasteners. If you still the 3/16 hole required for 1/4 inch tapcon. It still takes a lot of force to put them in even if you clean the hole out a couple of times. Witch may be weakening the Tapcon or partially breaking them. | Completed | 06/14/2020 | View / Edit Details | |||
Scott Zachman | 3m ramp | 03/21/2018 | 4 | PPE | Shipping with out proper Containment of silica By sub contractor | Completed | 03/22/2018 | View / Edit Details | |||
Scott Zachman | 3M ramp | 03/20/2018 | 6 | Housekeeping | Not pulling nails after taking 2 x 4’s down | Completed | 03/22/2018 | View / Edit Details | |||
Brent winter | 3rd bay | 12/22/2020 | 4 | Housekeeping | loose strand laying on the floor. | Completed | 12/22/2020 | View / Edit Details | |||
Brent winter | 3rd bay | 12/22/2020 | 4 | Housekeeping | loose strand laying on the floor. | Completed | 12/22/2020 | View / Edit Details | |||
Brent winter | 3rd bay | 09/09/2020 | 4 | PPE | Missing face shields by the strand pack. | Completed | 09/11/2020 | View / Edit Details | |||
Jeff Kemper | 3rd production bay | 06/12/2019 | 4 | Housekeeping | The area where the haunches are being poured had dried concrete on the floor and on the vibrator. Also, old rubber gloves lying on the floor. | Completed | 10/20/2020 | View / Edit Details | |||
Name | Location | Site | Area | Date | Ttl | Safety Topic | Root Causes | Status | Respirator User Name | Completion Date | Entry |