Iain SmithMountain States West Division Plant Indoor production03/18/20228Other

Power cord on FS3 column 13 cord reel has cut in cord sheath

Needs AttentionView / Edit Details
Thomas LarsonMountain States West Division Plant DT Staging03/18/20226Unsafe Operation

DT placed too close to dumpster. When placed, hit dumpster

Needs AttentionView / Edit Details
Alex TaylorMountain States West Division Plant TB203/18/20224Housekeeping

REINFORCING NOT PROPERLY STORED ON PALLETS

Needs AttentionView / Edit Details
gerald asmusMidwest Wells fs3903/18/20225Housekeeping

debris on floor

Completed03/18/2022View / Edit Details
Tim CateMountain States West Division Plant Outside supers office03/18/202210PPE

Truck parked on trash with strand in it

Needs AttentionView / Edit Details
Marc stynerGreat Lakes Valders - Production TT Bed03/17/20225PPE

Employee was seen using a cutting torch without a face shield.

Completed03/17/2022View / Edit Details
gerald asmusMidwest Wells FS2203/17/20225Unsafe Act

Employee not using stairs

Completed03/17/2022View / Edit Details
Danny SheetzMountain States West Division Field Outside casting bay/production03/17/20228Other

The drain line for the water cooler is making a mud hole and ice rink when cold from leaking on the ground and sidewalk.

Completed03/17/2022View / Edit Details
Jon bodartGreat Lakes Valders - Production flat south03/17/20226Unsafe Act

tucker driver hit exit sign with snout while backing into mixer. driver was avoiding employee who was sweeping floor

Completed03/25/2022View / Edit Details
Wade GakingGreat Lakes Valders - Production Plant 103/16/20227Housekeeping

There was a lot of cut strand laying by Gray bed the day before and today it was all cleaned up this morning 3/16/22.

Completed03/16/2022View / Edit Details
Marc staynerGreat Lakes Valders - Production Plant 203/16/20227Other

The breaks on the carpenters chop saw work intermittently.

Completed03/16/2022View / Edit Details
kristian zapataMountain States West Division Plant stripping03/16/20228Other

while stripping DT-3 the travel lift got stuck do to a large hole in the runway next to the bed.

Completed03/16/2022View / Edit Details
Joseph LinskensMountain States West Division Plant Staging03/16/20227Unsafe Act

Ladder stored improperly, unsecured

Completed03/16/2022View / Edit Details
Joseph LinskensMountain States West Division Plant Cut down Trucks03/16/20228Unsafe Operation

Caps missing on bottles for all 3 cut down trucks

Needs AttentionView / Edit Details
R RogersGreat Lakes Valders - Production BP 103/16/20227Unsafe Act

During the BP 1 discharge door replacement, one of the maintenance employees did not have his LOTO tag active - activity was stopped and discussion was completed. Next morning at the team huddle LOTO expectations were restated

Completed03/17/2022View / Edit Details
R RogersGreat Lakes Valders - Production WBC / yard03/16/20227Unsafe Operation

A trailer came into the maintenance hill that had chains wrapped around the landing gear and the one leg had cracks and damaged - this trailer took a trip with these issues

Needs AttentionView / Edit Details
UnknownGreat Lakes Valders - Production Plant 303/16/20223Other

Employee was walking past a strand pack when the strand came shooting out of the back on its own.

Completed03/17/2022View / Edit Details
Marc staynerGreat Lakes Valders - Production Hollowcore03/16/20226Fall Hazard

The net for the 4’ machine has multiple holes. We need to replace the net.

Completed03/17/2022View / Edit Details
John SchnellGreat Lakes Valders - Production Plant 3 - Bed 103/16/20228Unsafe Operation

Maintenance employees were welding new handles on a vibrating pan. They were doing the activity at the end of the bed near the stressing head while the strand were being stressed. They did not have any barrier up between them and the bed that was being stressed. They needed to be performing this work farther away from the bed.

Completed03/16/2022View / Edit Details
Tim cateMountain States West Division Plant QC lab03/16/20229Housekeeping

Trash left from finishing

Completed03/18/2022View / Edit Details
Tim cateMountain States West Division Plant QC lab03/16/20229Housekeeping

Trash left from finishing

Completed03/18/2022View / Edit Details
Wade GakingGreat Lakes Valders - Production Plant 203/15/20229Unsafe Operation

Witnessed stripping crew truck back over a pallet of PVC tubing breaking three of the tubes and crushing part of the pallet.

Completed03/16/2022View / Edit Details
Matthew FischerGreat Lakes Valders - Production DOT Middle line03/15/20223Other

At some point in the wind a 4' tall 40' long side form tipped over.

Completed03/16/2022View / Edit Details
Jon bodartGreat Lakes Valders - Production bed 103/15/20226Housekeeping

nail was sticking out of 2x4 causing hazard

Completed03/22/2022View / Edit Details
Jon bodartGreat Lakes Valders - Production east end plant 303/14/20225Housekeeping

rebar blocking man doir

Completed03/14/2022View / Edit Details