 Name LocationSite Area Date Ttl Safety Topic Root Causes Status Respirator User Name Completion DateEntry
DOUG E GALLEGOSMountain States West Division Field The Link at Fitzsimons02/26/20228Unsafe Operation

02/25/22
Doug Kler send Huan Anderson and Antonio Brito to install backer rod on 85" boom lift.
In this are there were PVC pipes stubs extended up 8" above the concrete slab to clear the bottom of the boom lift
Boom lift was in a position to reach every area they needed to work
On Saturday I walked the area and found that the lift had was moved and found 4 broken pipes with 1 broken pipe under the tire.
No one reported the broken pipes to Doug Kler or Myself at the end of shift on Friday
Trade Damage is not what we do.
To me this is careless and not paying attention to there surroundings by both employees

Needs AttentionView / Edit Details
Phyllis FelsingerGreat Lakes Valders - Production Yard04/23/20215Unsafe Operation

1. The new Hollow Core Yard layout appears too close to the power lines i.e, crane use and high tension wires.
2. Loads are set too close to the power lines.

Needs AttentionView / Edit Details
Dustin DetwilerMountain States West Division Plant Yard06/21/20217Housekeeping

1/2 Yard of concrete spilled on the East side of RS1

Needs AttentionView / Edit Details
Brian SchultzeMidwest Wells building 303/29/20226Fall Hazard

2 floor panels off the FS39 had no wood covers for the openings today. So the patch crew can put them of.

Needs AttentionView / Edit Details
Brenda FaberGreat Lakes Valders - Field Jobsite 22009007/02/20217Other

2 out of 4 notched pieces broke in transit. The pieces that broke could have fell off trailer and possibly hit other vehicles .

Needs AttentionView / Edit Details
Joseph LinskensMountain States West Division Plant Yard08/12/20218General Communication

2 panels stacked on top of an insulated architectural panel for empirical in row 6

Needs AttentionView / Edit Details
Tom KeltishGreat Lakes Valders - Production Lower roof of plant 301/19/20227Unsafe Act

2 shop employees were trying to get ice from the gutters. They were on the edge of the roof not tied off.

Needs AttentionView / Edit Details
Jeremy BlahnikGreat Lakes Valders - Production Plant 301/18/20226Unsafe Operation

3 Chopin sprayers are not labeled. They are located by the Aqua Film

Needs AttentionView / Edit Details
Joseph LinskensMountain States West Division Plant Yard08/12/20218General Communication

3 insulated panels for empirical stacked 3 high in row 7

Needs AttentionView / Edit Details
Joseph LinskensMountain States West Division Plant Yard08/12/20219General Communication

3 set ls of insulated panels stacked 3 high in row 6A

Needs AttentionView / Edit Details
Jon bodartGreat Lakes Valders - Production bed 101/06/20228Other

3/8" strand snapped during stressing. employee tapped on stressing chuck to remove and cable snapped at the chuck on the stressing plate

Needs AttentionView / Edit Details
Robert RogersGreat Lakes Valders - Production Hollow Core05/28/20216Unsafe Operation

4 foot machine had a Hydraulic hose leak Friday. The plane was to replace both lines - Been 4 to 5 years since the last change out - We made the hoses internal in the Maintenance Dept with the newer Hose clamp equipment - The Maintenance Tech followed the information on the crimp machine on which tools and settings based off the data sheet. Location of the fitting was not defined, and no one measured the crimp OD to ensure the crimp met expectations. We ended up with 2 leaks, the first one Sprayed the Tech in the face - Safety Glasses on! -Cleaned him up and the Maintenance Manager pulled the Maintenance Members together to review the process - Found many of the Techs did not know the proper process

Needs AttentionView / Edit Details
Dustin DetwilerMountain States West Division Plant East side supervisors office08/17/20215Chemical Exposure

5 Gallon bucket of transmission fluid was left by supervisors office and tipped over.

Needs AttentionView / Edit Details
Moises LopezMountain States West Division Plant Tool room12/08/202111Unsafe Operation

7 inch grainger set on vise press

Needs AttentionView / Edit Details
Robert WrightMountain States West Division Plant Staging after stripping Beams.08/26/202110Unsafe Operation

A beam is scratched. It looks to be by a Travelift. To my knowledge no one reported the incident. The scratches match a machine where the operator was just above scratches that match the beam. This is an operator issue because the groundperson should be on the opposite side

Needs AttentionView / Edit Details
Wade GakingGreat Lakes Valders - Production Plant 101/06/20227Housekeeping

A bundle of rebar on the right next to the south runway where a forklift can run over the bundle.

Needs AttentionView / Edit Details
Phyllis FelsingerGreat Lakes Crystal Lake - Production Wall bed05/27/20213Other

A door closer on the man door leading to the conveyor was broken.

Needs AttentionView / Edit Details
John SchnellGreat Lakes Valders - Production Where DT was removed (south of Plant 3)03/31/20217Fall Hazard

A double tee form was removed that exposed an open steam trench that was located under the bed. The open trench had a small cones in each corner which is inadequate protection around an open trench. We will be producing a slab to cover the opening but in the meantime Maintenance was instructed to place barriers around the open trench.

Needs AttentionView / Edit Details
josh stradalGreat Lakes Valders - Production yard06/10/20218Unsafe Act

A driver left with a load on the black and red slants. While in transportation he needed to slam on his brakes causing the racks to twist. No damage to the piece. We are still investigating this with all parties involved.

Needs AttentionView / Edit Details
Geoff NorrenaMountain States West Division Plant Mixer Washout Area03/08/20224PPE

A driver was chipping out concrete on the top of his truck, no ear plugs. I offered him some, he refused. It was really loud even 20 feet away.

Needs AttentionView / Edit Details
Brian SchultzeMidwest Wells Building 312/09/20216Fall Hazard

A DT8 panel came out today. The wood was coving the hole but a corner was pop up.

Needs AttentionView / Edit Details
Geoff NorrenaMountain States West Division Plant DT Staging Area10/22/20214Chemical Exposure

A finisher had a water bottle full of epoxy, and left it out in direct sunlight while he went to lunch.
after a long period of time, i happened to see the bubbling bottle leaking all over a weld plate on the bed, thought to immediately get it out of the sun. Turns out the bottle was incredibly hot, and mildly burned my fingers (not badly), even the employee with gloves on said he thought it was super hot too!
dangerous for unlabeled chemicals to be left unattended in the hot sun.

Needs AttentionView / Edit Details
Phyllis FelsingerGreat Lakes Valders - Production Along Railroad Tracks11/16/20216Other

A fox was observed walking east on the railroad tracks paralleling the main office parking lot.

Needs AttentionView / Edit Details
Phyllis FelsingerGreat Lakes Valders - Production Warehouse04/13/20216Other

A ladder was resting again a dumpster rather than stored properly. In addition, we are going to leaning ladders, this ladder is not of that type.

Needs AttentionView / Edit Details
Iain SmithMountain States West Division Plant East storage09/16/20218Fall Hazard

A large rec beam was placed at the very end of an 8x8 dunnage, causing the dunnage to crack and the beam to lean

Needs AttentionView / Edit Details